Well Manager® Applications
 


Temporary & Emergency Water Systems

PumpChamber

 
 
 
 

With a little engineering and a Well Manager® You can accomplish the improbable!

Follow these links to find solutions to some of the toughest well water supply problems you will face

BED & BREAKFASTS OPERATIONS USING A MARGINAL OR INADEQUATE WELL:

BOTTLING WATER:

CAMP GROUNDS:

CAR WASH: Operate a car wash using a well that appears to be grossly inadequate using a Well Manager®

CODE REQUIRED PLUMBING PERFORMANCE: Well Manager® and Herculan ConstaBoost systems were designed to provide code required plumbing performance using wells that cannot adequately do so on their own.

CONE OF INFLUENCE - SEE: INTRUSION OF SURFACE, SALT OR CONTAMINATED WATERS INTO POTABLE WATER WELLS: Reducing Cone of Influence and related problems using Well Manager®

CHURCHES: SEE HOUSES OF WORSHIP

DAIRY - INCREASE HERD USING UNDERSIZED WELL:

DROUGHT PLANNING AND WELL MANAGER:  During a drought, pond, lake and reservoir water levels drop because there is not enough rain to keep them full. These are the affects you can see but declining aquifer water levels, though they cannot be seen, cause economic and emotional hardships every bit as devastating for the huge number of people who depend on the groundwater wells that they supply.

DELIVERING STORED WATER: Pumping options. PumpChamber™ provides more water with smaller water storage tanks. Herculan ConstaBoost™ provides constant pressure, plenty of volume and is whisper quiet.

FOREST FIRE FIGHTING:

FIRE HOUSE: Filling Trucks and water storage tanks used to fill trucks

FIRE WATER STORAGE TANKS:

GARDENING

GROUND SOURCE HEAT PUMPS: Well Manager® used to maximize water supply and restore plumbing performance in systems with marginal well.

HOME FIRE SPRINKLER SYSTEMS:

HOUSES OF WORSHIP

HYDROFRACTING

INSURING SUSTAINABILITY OF PERFORMANCE IN WELL SUPPLIED SYSTEMS BY LIMITING WITHDRAWALS: Using a Well Manager® to insure plumbing will provide maximum performance far into the future - even during drought.

INTRUSION OF SURFACE, SALT OR CONTAMINATED WATERS INTO POTABLE WATER WELLS: Controlling problems related to Cone of Influence through time controlled pumping

IRRIGATION: INCLUDING FILLING irrigation PONDS  Has instructions for and a downloadable calculating spreadsheet that produces a graph to assist in the design of water storage for irrigation using low yield wells. Allows the user to try various well yield and storage configurations against a proposed irrigation design to determine if the well in question can run the proposed system using a Well Manager. And, if so, how much storage would be required.

LIVESTOCK: SUSTAIN BREEDING STOCK IN A DROUGHT: and make decisions regarding the number of animals that can be maintained based on well yield.

LONG PIPING RUNS: Restore pressure in buildings fed by long or undersized pipe runs connected to a well.

MULTIPLE BUILDINGS ON A SINGLE WELL SYSTEM: Using Well Manager® to supply pressure and volume to several buildings or a small development using an inadequate well.

OFFICE BUILDINGS

PLUMBING PERFORMANCE IN BUILDINGS CONNECTED TO A WELL: Well Manager® can get amazing amounts of water and provide great plumbing performance from the worst wells in the world.

RESIDENTIAL WATER STORAGE: Calculating spreadsheet produces a graph to assist in the design of Well Manager Systems for residential use. Enter your well yield and peak demand needs. Calculate the capabilities of the well over time, determine your peak demand water need and the amount of storage necessary to do the job. Resulting graph quickly tells whether or not the well in question can do the job. Graph also helps determine collection frequency for the job in question.

REVERSE ENGINEERING:

RV PARKS - SEE: CAMP GROUNDS

SCHOOLS & PLUMBING PERFORMANCE: School expansion, an increase in the student population or a decline in well yield can result in degradation of plumbing performance. Well Manager's® time based collection system is a perfect match for this time based use.

SEASONAL LOW YIELD: SEE: INSURING SUSTAINABILITY OF PERFORMANCE IN WELL SUPPLIED SYSTEMS BY LIMITING WITHDRAWALS

STOCK TANKS - FILLING:

TIME BASED PUMPING: Well Managers® timed pumping can reduce the Cone of Influence and eliminate problems related to it.

TIMED USES: Many uses are predictable because they occur at the same time each day. Knowing how much water you need and when you will need it makes Well Manager's® time based collection system a perfect match.

STORING WATER IN ABOVE GROUND TANKS: Well Manager® tank storage does not require treatment unless the well water is contaminated or the local authority requires it!

TREATMENT REQUIRED FOR STORED WATER: SEE storing water in tanks

WATER COLLECTION FROM LOW YIELD SOURCE: Slow and steady wins the race. Well Manager® and Aesop

WATER TOWER LEVEL & PRESSURE CONTROL:

YIELD DETERMINATION FOR VERY LOW YIELD WELLS: a simple method anyone can use to determine well yield

 


© 2010, Reid Plumbing Products, LLC  US: 800 211 8070  Worldwide: +1 609 466 4347